{"slug":"building-thermal-insulation-and-u-value-calculation-sheet","sheets":[{"name":"عزل الجدران الخارجية","maxRow":37,"maxCol":10,"colWidths":[8.0,48.0,18.0,18.0,26.0,26.0,18.0,22.0,24.0,46.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"حسابات العزل الحراري للجدران الخارجية والانتقالية الحرارية (U-Value) وفق كود البناء السعودي SBC 601","bg":"#1E3A8A","fg":"#FFFFFF","b":true,"al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":36.0,"cells":[{"c":"A2","v":"قالب تشغيلي لحساب المقاومة الحرارية الكلية (R-Value) ومعامل الانتقال الحراري (U-Value) متعدد الطبقات ومطابقة المنطقة المناخية | ISO 6946 / SASO","bg":"#DBEAFE","fg":"#475569","al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":28.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""},{"c":"G3","v":""},{"c":"H3","v":""},{"c":"I3","v":""},{"c":"J3","v":""}]},{"r":4,"h":34.0,"cells":[{"c":"A4","v":"معامل انتقال الحرارة للجدار U","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D4","v":"الحد الأقصى المسموح U-max","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"F4","v":"المقاومة الحرارية الكلية R-total","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I4","v":"حالة المطابقة للكود","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true}]},{"r":5,"h":44.0,"cells":[{"c":"A5","v":0.301,"f":"=ROUND(1/F23, 3)","bg":"#F1F5F9","fg":"#1E3A8A","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D5","v":0.34,"f":"=IF(F8=\"المنطقة 1 (الوسطى والشرقية)\", 0.34, IF(F8=\"المنطقة 2 (الغربية والساحلية)\", 0.39, 0.44))","bg":"#F1F5F9","fg":"#0F766E","b":true,"al":"center","cs":2},{"skip":true},{"c":"F5","v":3.32,"f":"=ROUND(F23, 3)","bg":"#F1F5F9","fg":"#334155","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I5","v":"مطابق لكود SBC 601","f":"=IF(A5<=D5, \"مطابق لكود SBC 601\", \"غير مطابق - يلزم زيادة العزل\")","bg":"#F1F5F9","fg":"#166534","b":true,"al":"center","cs":2},{"skip":true}]},{"r":6,"h":34.0,"cells":[{"c":"A6","v":"W/m²·K (المطلوب أقل من الحد الأقصى)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D6","v":"W/m²·K (كود SBC 601)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"F6","v":"m²·K/W (شاملة المقاومات السطحية)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I6","v":"الفحص النهائي لشركة الكهرباء","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true}]},{"r":7,"h":28.0,"cells":[{"c":"A7","v":""},{"c":"B7","v":""},{"c":"C7","v":""},{"c":"D7","v":""},{"c":"E7","v":""},{"c":"F7","v":""},{"c":"G7","v":""},{"c":"H7","v":""},{"c":"I7","v":""},{"c":"J7","v":""}]},{"r":8,"h":34.0,"cells":[{"c":"A8","v":"اسم المشروع / المبنى:","b":true,"al":"center","cs":2},{"skip":true},{"c":"C8","v":"مشروع برج سكني تجاري - الرياض","al":"center","cs":2},{"skip":true},{"c":"E8","v":"المنطقة المناخية:","b":true,"al":"center"},{"c":"F8","v":"المنطقة 1 (الوسطى والشرقية)","fg":"#1E3A8A","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I8","v":"نوع الإشغال:","b":true,"al":"center"},{"c":"J8","v":"سكني / تجاري","al":"center"}]},{"r":9,"h":34.0,"cells":[{"c":"A9","v":""},{"c":"B9","v":""},{"c":"C9","v":""},{"c":"D9","v":""},{"c":"E9","v":""},{"c":"F9","v":""},{"c":"G9","v":""},{"c":"H9","v":""},{"c":"I9","v":""},{"c":"J9","v":""}]},{"r":10,"h":28.0,"cells":[{"c":"A10","v":""},{"c":"B10","v":""},{"c":"C10","v":""},{"c":"D10","v":""},{"c":"E10","v":""},{"c":"F10","v":""},{"c":"G10","v":""},{"c":"H10","v":""},{"c":"I10","v":""},{"c":"J10","v":""}]},{"r":11,"h":40.0,"cells":[{"c":"A11","v":"م","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B11","v":"وصف طبقة الجدار (من الداخل إلى الخارج)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C11","v":"السماكة d (ملم)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D11","v":"السماكة d (متر)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E11","v":"معامل التوصيل الحراري λ (W/m·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F11","v":"المقاومة الحرارية R (m²·K/W)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"G11","v":"الكثافة ρ (kg/m³)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"H11","v":"السعة الحرارية النوعية","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"I11","v":"المرجع القياسي","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"J11","v":"ملاحظات وتفاصيل التثبيت","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":12,"h":36.0,"cells":[{"c":"A12","v":1,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B12","v":"مقاومة السطح الداخلي Rsi (تدفق أفقي للحرارة)","bg":"#F8FAFC"},{"c":"C12","v":"-","bg":"#F8FAFC","al":"center"},{"c":"D12","v":"-","bg":"#F8FAFC","al":"center"},{"c":"E12","v":"-","bg":"#F8FAFC","al":"center"},{"c":"F12","v":0.13,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"G12","v":"-","bg":"#F8FAFC","al":"center"},{"c":"H12","v":"-","bg":"#F8FAFC","al":"center"},{"c":"I12","v":"ISO 6946 / SBC 601","bg":"#F8FAFC","al":"center"},{"c":"J12","v":"قيمة قياسية لانتقال الحرارة بالحمل والإشعاع داخلياً","bg":"#F8FAFC"}]},{"r":13,"h":36.0,"cells":[{"c":"A13","v":2,"b":true,"al":"center"},{"c":"B13","v":"بياض أسمنتي داخلي (محارة ناعمة)"},{"c":"C13","v":20,"in":true,"al":"center","nf":"#,##0"},{"c":"D13","v":0.02,"f":"=C13/1000","al":"center"},{"c":"E13","v":0.72,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F13","v":0.028,"f":"=ROUND(D13/E13, 3)","b":true,"al":"center"},{"c":"G13","v":1850,"in":true,"al":"center","nf":"#,##0"},{"c":"H13","v":1000,"in":true,"al":"center"},{"c":"I13","v":"SBC 601 Table 5.1","al":"center"},{"c":"J13","v":"طبقة تشطيب داخلي ودهان أساس مائي"}]},{"r":14,"h":36.0,"cells":[{"c":"A14","v":3,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B14","v":"بلوك خرساني مفرغ عالي الجودة (سماكة 20 سم)","bg":"#F8FAFC"},{"c":"C14","v":200,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D14","v":0.2,"f":"=C14/1000","bg":"#F8FAFC","al":"center"},{"c":"E14","v":0.9,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F14","v":0.222,"f":"=ROUND(D14/E14, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G14","v":1400,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H14","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I14","v":"ASTM C90 / SASO","bg":"#F8FAFC","al":"center"},{"c":"J14","v":"جدار حامل أو قواطع مع مونة الربط الأسمنتية","bg":"#F8FAFC"}]},{"r":15,"h":36.0,"cells":[{"c":"A15","v":4,"b":true,"al":"center"},{"c":"B15","v":"ألواح عازل حراري بوليسترين مبثوق XPS كثافة 35"},{"c":"C15","v":75,"in":true,"al":"center","nf":"#,##0"},{"c":"D15","v":0.075,"f":"=C15/1000","al":"center"},{"c":"E15","v":0.028,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F15","v":2.679,"f":"=ROUND(D15/E15, 3)","b":true,"al":"center"},{"c":"G15","v":35,"in":true,"al":"center","nf":"#,##0"},{"c":"H15","v":1450,"in":true,"al":"center"},{"c":"I15","v":"SASO 2884 / ASTM C578","al":"center"},{"c":"J15","v":"حواف متداخلة (Shiplap) لمنع الجسور الحرارية"}]},{"r":16,"h":36.0,"cells":[{"c":"A16","v":5,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B16","v":"فراغ هوائي غير مهوى (Air Cavity)","bg":"#F8FAFC"},{"c":"C16","v":30,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D16","v":0.03,"f":"=C16/1000","bg":"#F8FAFC","al":"center"},{"c":"E16","v":"-","bg":"#F8FAFC","al":"center"},{"c":"F16","v":0.18,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"G16","v":1.2,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H16","v":1005,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I16","v":"ISO 6946 Table 2","bg":"#F8FAFC","al":"center"},{"c":"J16","v":"فراغ بين العازل والكسوة الخارجية بحزام تثبيت","bg":"#F8FAFC"}]},{"r":17,"h":36.0,"cells":[{"c":"A17","v":6,"b":true,"al":"center"},{"c":"B17","v":"بياض أسمنتي خارجي خشن مع مادة مانعة للرطوبة"},{"c":"C17","v":20,"in":true,"al":"center","nf":"#,##0"},{"c":"D17","v":0.02,"f":"=C17/1000","al":"center"},{"c":"E17","v":0.85,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F17","v":0.024,"f":"=ROUND(D17/E17, 3)","b":true,"al":"center"},{"c":"G17","v":1900,"in":true,"al":"center","nf":"#,##0"},{"c":"H17","v":1000,"in":true,"al":"center"},{"c":"I17","v":"SBC 601 Table 5.1","al":"center"},{"c":"J17","v":"طبقة تأسيس تحت الكسوة أو دهان بروفايل"}]},{"r":18,"h":36.0,"cells":[{"c":"A18","v":7,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B18","v":"كسوة حجر طبيعي مثبت بالطريقة الميكانيكية","bg":"#F8FAFC"},{"c":"C18","v":30,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D18","v":0.03,"f":"=C18/1000","bg":"#F8FAFC","al":"center"},{"c":"E18","v":1.8,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F18","v":0.017,"f":"=ROUND(D18/E18, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G18","v":2600,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H18","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I18","v":"ASTM C615","bg":"#F8FAFC","al":"center"},{"c":"J18","v":"تثبيت بمرابط ستانلس ستيل مع فواصل تمدد","bg":"#F8FAFC"}]},{"r":19,"h":36.0,"cells":[{"c":"A19","v":8,"b":true,"al":"center"},{"c":"B19","v":"مقاومة السطح الخارجي Rse (معرض للرياح والجو الخارجي)"},{"c":"C19","v":"-","al":"center"},{"c":"D19","v":"-","al":"center"},{"c":"E19","v":"-","al":"center"},{"c":"F19","v":0.04,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"G19","v":"-","al":"center"},{"c":"H19","v":"-","al":"center"},{"c":"I19","v":"ISO 6946 / SBC 601","al":"center"},{"c":"J19","v":"قيمة قياسية للانتقال الحراري السطحي الخارجي"}]},{"r":20,"h":28.0,"cells":[{"c":"A20","v":""},{"c":"B20","v":""},{"c":"C20","v":""},{"c":"D20","v":""},{"c":"E20","v":""},{"c":"F20","v":""},{"c":"G20","v":""},{"c":"H20","v":""},{"c":"I20","v":""},{"c":"J20","v":""}]},{"r":21,"h":28.0,"cells":[{"c":"A21","v":""},{"c":"B21","v":""},{"c":"C21","v":""},{"c":"D21","v":""},{"c":"E21","v":""},{"c":"F21","v":""},{"c":"G21","v":""},{"c":"H21","v":""},{"c":"I21","v":""},{"c":"J21","v":""}]},{"r":22,"h":28.0,"cells":[{"c":"A22","v":""},{"c":"B22","v":""},{"c":"C22","v":""},{"c":"D22","v":""},{"c":"E22","v":""},{"c":"F22","v":""},{"c":"G22","v":""},{"c":"H22","v":""},{"c":"I22","v":""},{"c":"J22","v":""}]},{"r":23,"h":42.0,"cells":[{"c":"A23","v":"إجمالي المقاومة الحرارية لجدار المبنى (R-Total):","bg":"#E2E8F0","fg":"#1E3A8A","b":true,"al":"center","cs":2},{"skip":true},{"c":"C23","v":375,"f":"=SUM(C13:C18)","bg":"#E2E8F0","b":true,"al":"center"},{"c":"D23","v":0.375,"f":"=ROUND(C23/1000, 3)","bg":"#E2E8F0","b":true,"al":"center"},{"c":"E23","v":"-","bg":"#E2E8F0","al":"center"},{"c":"F23","v":3.32,"f":"=SUM(F12:F19)","bg":"#E2E8F0","fg":"#1E3A8A","b":true,"al":"center","nf":"#,##0.000"},{"c":"G23","v":"معامل U للجدار = 1 / R-Total = ","bg":"#E2E8F0","fg":"#047857","b":true,"al":"center","cs":4},{"skip":true},{"skip":true},{"skip":true}]},{"r":24,"h":28.0,"cells":[{"c":"A24","v":""},{"c":"B24","v":""},{"c":"C24","v":""},{"c":"D24","v":""},{"c":"E24","v":""},{"c":"F24","v":""},{"c":"G24","v":""},{"c":"H24","v":""},{"c":"I24","v":""},{"c":"J24","v":""}]},{"r":25,"h":38.0,"cells":[{"c":"A25","v":"مصفوفة مقارنة أنظمة بناء الجدران الشائعة ومطابقتها لكود SBC 601 (سماكة العزل المطلوبة للوصول إلى U ≤ 0.34)","bg":"#0F766E","fg":"#FFFFFF","b":true,"al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":26,"h":40.0,"cells":[{"c":"A26","v":"م","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B26","v":"نظام بناء الجدار الخارجي","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C26","v":"مكونات الطبقة العازلة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D26","v":"سماكة العزل (ملم)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E26","v":"معامل λ (W/m·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F26","v":"المقاومة R (m²·K/W)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"G26","v":"معامل U (W/m²·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"H26","v":"الحد الأقصى U-max","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"I26","v":"حالة المطابقة للمنطقة 1","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"J26","v":"التقييم الفني والتكلفة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":27,"h":36.0,"cells":[{"c":"A27","v":1,"b":true,"al":"center"},{"c":"B27","v":"نظام الجدار المزدوج (Double Wall with Cavity)"},{"c":"C27","v":"ألواح صوف صخري Rockwool كثافة 60","al":"center"},{"c":"D27","v":75,"in":true,"al":"center"},{"c":"E27","v":0.034,"in":true,"al":"center"},{"c":"F27","v":2.78,"in":true,"al":"center"},{"c":"G27","v":0.36,"in":true,"b":true,"al":"center"},{"c":"H27","v":0.34,"in":true,"al":"center"},{"c":"I27","v":"غير مطابق (يلزم 80 ملم)","bg":"#FEF3C7","fg":"#92400E","b":true,"al":"center"},{"c":"J27","v":"عزل صوتي وحراري ممتاز ومقاومة حريق A1"}]},{"r":28,"h":52.0,"cells":[{"c":"A28","v":2,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B28","v":"جدار مزدوج بعازل بوليسترين مبثوق XPS","bg":"#F8FAFC"},{"c":"C28","v":"ألواح XPS كثافة 35 كجم/م³","bg":"#F8FAFC","al":"center"},{"c":"D28","v":75,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"E28","v":0.028,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"F28","v":3.25,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G28","v":0.308,"in":true,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"H28","v":0.34,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I28","v":"مطابق لكود SBC 601","bg":"#DCFCE7","fg":"#166534","b":true,"al":"center"},{"c":"J28","v":"النظام الأكثر انتشاراً ومقاومة امتصاص الماء","bg":"#F8FAFC"}]},{"r":29,"h":52.0,"cells":[{"c":"A29","v":3,"b":true,"al":"center"},{"c":"B29","v":"جدار البلوك الخرساني الخلوي المعقم (سيبوريكس AAC)"},{"c":"C29","v":"مادة الخرسانة الخلوية بحد ذاتها","al":"center"},{"c":"D29","v":250,"in":true,"al":"center"},{"c":"E29","v":0.12,"in":true,"al":"center"},{"c":"F29","v":2.35,"in":true,"al":"center"},{"c":"G29","v":0.425,"in":true,"b":true,"al":"center"},{"c":"H29","v":0.34,"in":true,"al":"center"},{"c":"I29","v":"يلزم زيادة السماكة لـ 30 سم","bg":"#FEF3C7","fg":"#92400E","b":true,"al":"center"},{"c":"J29","v":"خفيف الوزن وسهل التمديدات ويوفر بالهيكل"}]},{"r":30,"h":52.0,"cells":[{"c":"A30","v":4,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B30","v":"نظام العزل الحراري الخارجي المستمر (EIFS)","bg":"#F8FAFC"},{"c":"C30","v":"ألواح بوليسترين ممدد EPS كثافة 20","bg":"#F8FAFC","al":"center"},{"c":"D30","v":80,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"E30","v":0.034,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"F30","v":2.95,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G30","v":0.339,"in":true,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"H30","v":0.34,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I30","v":"مطابق لكود SBC 601","bg":"#DCFCE7","fg":"#166534","b":true,"al":"center"},{"c":"J30","v":"يقضي تماماً على الجسور الحرارية بالأعمدة والكمرات","bg":"#F8FAFC"}]},{"r":31,"h":52.0,"cells":[{"c":"A31","v":5,"b":true,"al":"center"},{"c":"B31","v":"بلوك بركاني معزول بحقن البولي يوريثان PUR"},{"c":"C31","v":"فوم بولي يوريثان محقون داخل البلوك","al":"center"},{"c":"D31","v":60,"in":true,"al":"center"},{"c":"E31","v":0.023,"in":true,"al":"center"},{"c":"F31","v":3.1,"in":true,"al":"center"},{"c":"G31","v":0.322,"in":true,"b":true,"al":"center"},{"c":"H31","v":0.34,"in":true,"al":"center"},{"c":"I31","v":"مطابق لكود SBC 601","bg":"#DCFCE7","fg":"#166534","b":true,"al":"center"},{"c":"J31","v":"سرعة تنفيذ وجودة مصنعية بدون جدارين"}]},{"r":32,"h":28.0,"cells":[{"c":"A32","v":""},{"c":"B32","v":""},{"c":"C32","v":""},{"c":"D32","v":""},{"c":"E32","v":""},{"c":"F32","v":""},{"c":"G32","v":""},{"c":"H32","v":""},{"c":"I32","v":""},{"c":"J32","v":""}]},{"r":33,"h":34.0,"cells":[{"c":"A33","v":"اشتراطات كود البناء السعودي SBC 601 لشهادة إتمام البناء وإطلاق التيار الكهربائي:","fg":"#1E3A8A","b":true,"al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":34,"h":34.0,"cells":[{"c":"A34","v":"1. إلزامية عزل كافة العناصر الإنشائية الخارجية (جدران، أعمدة، كمرات، أسقف) لمنع الجسور الحرارية (Thermal Bridges).","fg":"#334155","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":35,"h":34.0,"cells":[{"c":"A35","v":"2. يشترط في العوازل المستخدمة الحصول على علامة الجودة السعودية (SASO Quality Mark) وبطاقة كفاءة الطاقة وترشيد الاستهلاك.","fg":"#334155","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":36,"h":34.0,"cells":[{"c":"A36","v":"3. تخضع المنشأة لمعاينة حقلية وفحص بالكاميرات الحرارية (Thermal Infrared Camera) من قِبل مهندسي شركة الكهرباء قبل إطلاق التيار.","fg":"#334155","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":37,"h":34.0,"cells":[{"c":"A37","v":"4. توفر سماكة العزل المطابقة لكود SBC 601 ما بين 35% إلى 50% من استهلاك أجهزة التكييف السنوية للطاقة الكهربائية.","fg":"#334155","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]}]},{"name":"عزل الأسقف والأسطح","maxRow":22,"maxCol":10,"colWidths":[8.0,48.0,18.0,18.0,26.0,26.0,18.0,22.0,24.0,46.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"حسابات العزل الحراري للأسقف والأسطح الأخيرة (Roof U-Value) وفق كود SBC 601 / SBC 602","bg":"#1E3A8A","fg":"#FFFFFF","b":true,"al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":36.0,"cells":[{"c":"A2","v":"حساب المقاومة الحرارية للأسقف الخرسانية المعزولة بنظام السطح المقلوب (Inverted Roof) والسطح التقليدي ومؤشر الانعكاس الشمسي SRI","bg":"#DBEAFE","fg":"#475569","al":"center","cs":10},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":28.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""},{"c":"G3","v":""},{"c":"H3","v":""},{"c":"I3","v":""},{"c":"J3","v":""}]},{"r":4,"h":34.0,"cells":[{"c":"A4","v":"معامل انتقال الحرارة للسقف U-roof","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D4","v":"الحد الأقصى المسموح للسقف U-max","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"F4","v":"إجمالي مقاومة السقف R-roof","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I4","v":"حالة المطابقة للسطح الأخير","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true}]},{"r":5,"h":44.0,"cells":[{"c":"A5","v":0.246,"f":"=ROUND(1/F22, 3)","bg":"#F1F5F9","fg":"#1E3A8A","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D5","v":0.2,"f":"=IF(F8=\"المنطقة 1 (الوسطى والشرقية)\", 0.20, IF(F8=\"المنطقة 2 (الغربية والساحلية)\", 0.24, 0.28))","bg":"#F1F5F9","fg":"#0F766E","b":true,"al":"center","cs":2},{"skip":true},{"c":"F5","v":4.072,"f":"=ROUND(F22, 3)","bg":"#F1F5F9","fg":"#334155","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I5","v":"غير مطابق - يتطلب عازل أسمك","f":"=IF(A5<=D5, \"مطابق لكود SBC 601 للأسقف\", \"غير مطابق - يتطلب عازل أسمك\")","bg":"#F1F5F9","fg":"#166534","b":true,"al":"center","cs":2},{"skip":true}]},{"r":6,"h":34.0,"cells":[{"c":"A6","v":"W/m²·K (الحد الأقصى لكود SBC هو 0.20)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":3},{"skip":true},{"skip":true},{"c":"D6","v":"W/m²·K (كود SBC 601 للأسطح)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"F6","v":"m²·K/W (شاملة طبقات الخرسانة والميول)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I6","v":"فحص العزل الحراري والمائي للسطح","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true}]},{"r":7,"h":28.0,"cells":[{"c":"A7","v":""},{"c":"B7","v":""},{"c":"C7","v":""},{"c":"D7","v":""},{"c":"E7","v":""},{"c":"F7","v":""},{"c":"G7","v":""},{"c":"H7","v":""},{"c":"I7","v":""},{"c":"J7","v":""}]},{"r":8,"h":52.0,"cells":[{"c":"A8","v":"نظام عزل السطح المطبق:","b":true,"al":"center","cs":2},{"skip":true},{"c":"C8","v":"نظام السطح المقلوب (Inverted Protected Membrane)","al":"center","cs":2},{"skip":true},{"c":"E8","v":"المنطقة المناخية:","b":true,"al":"center"},{"c":"F8","v":"المنطقة 1 (الوسطى والشرقية)","fg":"#1E3A8A","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"I8","v":"الانعكاسية الشمسية SRI:","b":true,"al":"center"},{"c":"J8","v":"SRI ≥ 78 (بلاط عاكس)","al":"center"}]},{"r":9,"h":28.0,"cells":[{"c":"A9","v":""},{"c":"B9","v":""},{"c":"C9","v":""},{"c":"D9","v":""},{"c":"E9","v":""},{"c":"F9","v":""},{"c":"G9","v":""},{"c":"H9","v":""},{"c":"I9","v":""},{"c":"J9","v":""}]},{"r":10,"h":40.0,"cells":[{"c":"A10","v":"م","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B10","v":"وصف طبقة السقف والسطح الأخير","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C10","v":"السماكة d (ملم)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D10","v":"السماكة d (متر)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E10","v":"معامل التوصيل الحراري λ (W/m·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F10","v":"المقاومة الحرارية R (m²·K/W)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"G10","v":"الكثافة ρ (kg/m³)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"H10","v":"السعة الحرارية النوعية","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"I10","v":"المرجع والمواصفة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"J10","v":"الوظيفة الهندسية للطبقة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":11,"h":36.0,"cells":[{"c":"A11","v":1,"b":true,"al":"center"},{"c":"B11","v":"مقاومة السطح الداخلي Rsi (تدفق حراري رأسي لأعلى في التبريد)"},{"c":"C11","v":"-","al":"center"},{"c":"D11","v":"-","al":"center"},{"c":"E11","v":"-","al":"center"},{"c":"F11","v":0.1,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"G11","v":"-","al":"center"},{"c":"H11","v":"-","al":"center"},{"c":"I11","v":"ISO 6946 / SBC 601","al":"center"},{"c":"J11","v":"معامل انتقال الحرارة السطحي للأسقف"}]},{"r":12,"h":36.0,"cells":[{"c":"A12","v":2,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B12","v":"بياض أسمنتي داخلي للأسقف (محارة سقف)","bg":"#F8FAFC"},{"c":"C12","v":15,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D12","v":0.015,"f":"=C12/1000","bg":"#F8FAFC","al":"center"},{"c":"E12","v":0.72,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F12","v":0.021,"f":"=ROUND(D12/E12, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G12","v":1850,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H12","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I12","v":"SBC 601 Table 5.1","bg":"#F8FAFC","al":"center"},{"c":"J12","v":"تسوية وتشطيب أسفل بلاطة الخرسانة","bg":"#F8FAFC"}]},{"r":13,"h":36.0,"cells":[{"c":"A13","v":3,"b":true,"al":"center"},{"c":"B13","v":"بلاطة خرسانية مسلحة (سقف الدور الأخير)"},{"c":"C13","v":200,"in":true,"al":"center","nf":"#,##0"},{"c":"D13","v":0.2,"f":"=C13/1000","al":"center"},{"c":"E13","v":1.75,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F13","v":0.114,"f":"=ROUND(D13/E13, 3)","b":true,"al":"center"},{"c":"G13","v":2400,"in":true,"al":"center","nf":"#,##0"},{"c":"H13","v":1000,"in":true,"al":"center"},{"c":"I13","v":"SBC 304 / ACI 318","al":"center"},{"c":"J13","v":"العنصر الإنشائي الحامل والكتلة الحرارية (Thermal Mass)"}]},{"r":14,"h":36.0,"cells":[{"c":"A14","v":4,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B14","v":"خرسانة رغوية خفيفة أو مونة ميول السطح (Slope Screed)","bg":"#F8FAFC"},{"c":"C14","v":70,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D14","v":0.07,"f":"=C14/1000","bg":"#F8FAFC","al":"center"},{"c":"E14","v":0.41,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F14","v":0.171,"f":"=ROUND(D14/E14, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G14","v":1200,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H14","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I14","v":"ASTM C869","bg":"#F8FAFC","al":"center"},{"c":"J14","v":"توجيه مياه الأمطار نحو المزاريب بنسبة ميل 1% إلى 1.5%","bg":"#F8FAFC"}]},{"r":15,"h":36.0,"cells":[{"c":"A15","v":5,"b":true,"al":"center"},{"c":"B15","v":"لفائف عازل مائي ممبرين بيتوميني معدل SBS سماكة 4 ملم"},{"c":"C15","v":4,"in":true,"al":"center","nf":"#,##0"},{"c":"D15","v":0.004,"f":"=C15/1000","al":"center"},{"c":"E15","v":0.23,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F15","v":0.017,"f":"=ROUND(D15/E15, 3)","b":true,"al":"center"},{"c":"G15","v":1100,"in":true,"al":"center","nf":"#,##0"},{"c":"H15","v":1450,"in":true,"al":"center"},{"c":"I15","v":"ASTM D6164","al":"center"},{"c":"J15","v":"مانع تسرب المياه التام ملحوم باللهب مع برايمر"}]},{"r":16,"h":36.0,"cells":[{"c":"A16","v":6,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B16","v":"ألواح عازل حراري بوليسترين مبثوق XPS كثافة 35 مجهزة بدرج","bg":"#F8FAFC"},{"c":"C16","v":100,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D16","v":0.1,"f":"=C16/1000","bg":"#F8FAFC","al":"center"},{"c":"E16","v":0.028,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F16","v":3.571,"f":"=ROUND(D16/E16, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G16","v":35,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H16","v":1450,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I16","v":"SASO 2884 / ASTM C578","bg":"#F8FAFC","al":"center"},{"c":"J16","v":"حماية العازل المائي وعزل حراري فائق للسطح المقلوب","bg":"#F8FAFC"}]},{"r":17,"h":36.0,"cells":[{"c":"A17","v":7,"b":true,"al":"center"},{"c":"B17","v":"طبقة نسيج جيوتكستايل غير منسوج فاصل ومرشح (Filter Layer)"},{"c":"C17","v":2,"in":true,"al":"center","nf":"#,##0"},{"c":"D17","v":0.002,"f":"=C17/1000","al":"center"},{"c":"E17","v":0.13,"in":true,"al":"center","nf":"#,##0.000"},{"c":"F17","v":0.015,"f":"=ROUND(D17/E17, 3)","b":true,"al":"center"},{"c":"G17","v":200,"in":true,"al":"center","nf":"#,##0"},{"c":"H17","v":1800,"in":true,"al":"center"},{"c":"I17","v":"ASTM D4751","al":"center"},{"c":"J17","v":"فصل العازل ومنع تسرب الأتربة مع نفاذية المياه"}]},{"r":18,"h":36.0,"cells":[{"c":"A18","v":8,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B18","v":"بلاط موزايكو أبيض عاكس للحرارة مع فواصل تمدد مطاطية","bg":"#F8FAFC"},{"c":"C18","v":30,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"D18","v":0.03,"f":"=C18/1000","bg":"#F8FAFC","al":"center"},{"c":"E18","v":1.3,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0.000"},{"c":"F18","v":0.023,"f":"=ROUND(D18/E18, 3)","bg":"#F8FAFC","b":true,"al":"center"},{"c":"G18","v":2300,"in":true,"bg":"#F8FAFC","al":"center","nf":"#,##0"},{"c":"H18","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"I18","v":"SASO 1032","bg":"#F8FAFC","al":"center"},{"c":"J18","v":"حماية ميكانيكية وانعكاس أشعة الشمس الفوق بنفسجية","bg":"#F8FAFC"}]},{"r":19,"h":36.0,"cells":[{"c":"A19","v":9,"b":true,"al":"center"},{"c":"B19","v":"مقاومة السطح الخارجي Rse (سطح مكشوف للرياح والجو)"},{"c":"C19","v":"-","al":"center"},{"c":"D19","v":"-","al":"center"},{"c":"E19","v":"-","al":"center"},{"c":"F19","v":0.04,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"G19","v":"-","al":"center"},{"c":"H19","v":"-","al":"center"},{"c":"I19","v":"ISO 6946 / SBC 601","al":"center"},{"c":"J19","v":"معامل انتقال الحرارة السطحي الخارجي"}]},{"r":20,"h":28.0,"cells":[{"c":"A20","v":""},{"c":"B20","v":""},{"c":"C20","v":""},{"c":"D20","v":""},{"c":"E20","v":""},{"c":"F20","v":""},{"c":"G20","v":""},{"c":"H20","v":""},{"c":"I20","v":""},{"c":"J20","v":""}]},{"r":21,"h":28.0,"cells":[{"c":"A21","v":""},{"c":"B21","v":""},{"c":"C21","v":""},{"c":"D21","v":""},{"c":"E21","v":""},{"c":"F21","v":""},{"c":"G21","v":""},{"c":"H21","v":""},{"c":"I21","v":""},{"c":"J21","v":""}]},{"r":22,"h":42.0,"cells":[{"c":"A22","v":"إجمالي المقاومة الحرارية لسقف المبنى (R-Total):","bg":"#E2E8F0","fg":"#1E3A8A","b":true,"al":"center","cs":2},{"skip":true},{"c":"C22","v":421,"f":"=SUM(C12:C18)","bg":"#E2E8F0","b":true,"al":"center"},{"c":"D22","v":0.421,"f":"=ROUND(C22/1000, 3)","bg":"#E2E8F0","b":true,"al":"center"},{"c":"E22","v":"-","bg":"#E2E8F0","al":"center"},{"c":"F22","v":4.072,"f":"=SUM(F11:F19)","bg":"#E2E8F0","fg":"#1E3A8A","b":true,"al":"center","nf":"#,##0.000"},{"c":"G22","v":"معامل U للسقف = 1 / R-Total = ","bg":"#E2E8F0","fg":"#047857","b":true,"al":"center","cs":4},{"skip":true},{"skip":true},{"skip":true}]}]},{"name":"النوافذ والواجهات الزجاجية","maxRow":15,"maxCol":9,"colWidths":[8.0,46.0,18.0,22.0,22.0,18.0,22.0,26.0,26.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"حسابات كفاءة النوافذ والواجهات الزجاجية ونسبة التهديف (WWR) وفق كود SBC 601 / SBC 602","bg":"#1E3A8A","fg":"#FFFFFF","b":true,"al":"center","cs":9},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":36.0,"cells":[{"c":"A2","v":"حساب معامل الانتقال الحراري للزجاج (U-factor) ومعامل الكسب الحراري الشمسي (SHGC) ونفاذية الضوء (VT)","bg":"#DBEAFE","fg":"#475569","al":"center","cs":9},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":28.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""},{"c":"G3","v":""},{"c":"H3","v":""},{"c":"I3","v":""}]},{"r":4,"h":34.0,"cells":[{"c":"A4","v":"نسبة مساحة النوافذ WWR","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"C4","v":"معامل انتقال حرارة الزجاج U","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"E4","v":"معامل الكسب الشمسي SHGC","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"H4","v":"حالة مطابقة الواجهات الزجاجية","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true}]},{"r":5,"h":44.0,"cells":[{"c":"A5","v":"20.8%","f":"=ROUND(D8/B8*100, 1) & \"%\"","bg":"#F1F5F9","fg":"#1E3A8A","b":true,"al":"center","cs":2},{"skip":true},{"c":"C5","v":"1.90","bg":"#F1F5F9","fg":"#0F766E","b":true,"al":"center","cs":2},{"skip":true},{"c":"E5","v":"0.24","bg":"#F1F5F9","fg":"#334155","b":true,"al":"center","cs":3},{"skip":true},{"skip":true},{"c":"H5","v":"مطابق لاشتراطات SBC 601","bg":"#F1F5F9","fg":"#166534","b":true,"al":"center","cs":2},{"skip":true}]},{"r":6,"h":34.0,"cells":[{"c":"A6","v":"الحد الأقصى المسموح 25% سكني / 40% تجاري","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"C6","v":"W/m²·K (زجاج مزدوج Low-E مع غاز الأرجون)","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"E6","v":"أقل من الحد الأقصى لكود SBC 601 وهو 0.25","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":3},{"skip":true},{"skip":true},{"c":"H6","v":"مستوفٍ لاشتراطات كفاءة الطاقة","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true}]},{"r":7,"h":28.0,"cells":[{"c":"A7","v":""},{"c":"B7","v":""},{"c":"C7","v":""},{"c":"D7","v":""},{"c":"E7","v":""},{"c":"F7","v":""},{"c":"G7","v":""},{"c":"H7","v":""},{"c":"I7","v":""}]},{"r":8,"h":104.0,"cells":[{"c":"A8","v":"إجمالي مساحة الجدران الخارجية:","b":true,"al":"center"},{"c":"B8","v":650,"in":true,"b":true,"al":"center"},{"c":"C8","v":"إجمالي مساحة النوافذ:","b":true,"al":"center"},{"c":"D8","v":135,"in":true,"b":true,"al":"center"},{"c":"E8","v":"نوع إطار النوافذ:","b":true,"al":"center","cs":2},{"skip":true},{"c":"G8","v":"ألومنيوم معزول حرارياً مع جسر كسر حراري (Thermal Break)","fg":"#1E3A8A","b":true,"al":"center","cs":3},{"skip":true},{"skip":true}]},{"r":9,"h":28.0,"cells":[{"c":"A9","v":""},{"c":"B9","v":""},{"c":"C9","v":""},{"c":"D9","v":""},{"c":"E9","v":""},{"c":"F9","v":""},{"c":"G9","v":""},{"c":"H9","v":""},{"c":"I9","v":""}]},{"r":10,"h":40.0,"cells":[{"c":"A10","v":"م","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B10","v":"نوع وتركيب الزجاج والإطار","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C10","v":"سماكة الزجاج (ملم)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D10","v":"معامل U للزجاج (W/m²·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E10","v":"معامل U الكلي مع الإطار","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F10","v":"معامل SHGC","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"G10","v":"نفاذية الضوء المرئي VT","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"H10","v":"الحد الأقصى المسموح SBC 601","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"I10","v":"حالة المطابقة للكود","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":11,"h":36.0,"cells":[{"c":"A11","v":1,"b":true,"al":"center"},{"c":"B11","v":"زجاج مفرد شفاف 6 ملم مع إطار ألومنيوم عادي (Single Clear)"},{"c":"C11","v":6,"in":true,"al":"center"},{"c":"D11","v":5.7,"in":true,"al":"center"},{"c":"E11","v":6.2,"in":true,"b":true,"al":"center"},{"c":"F11","v":0.82,"in":true,"al":"center"},{"c":"G11","v":0.88,"in":true,"al":"center"},{"c":"H11","v":"U ≤ 2.67 / SHGC ≤ 0.25","al":"center"},{"c":"I11","v":"غير مطابق إطلاقاً","bg":"#FEE2E2","fg":"#991B1B","b":true,"al":"center"}]},{"r":12,"h":36.0,"cells":[{"c":"A12","v":2,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B12","v":"زجاج مزدوج شفاف 6+12+6 ملم فراغ هواء وإطار عادي","bg":"#F8FAFC"},{"c":"C12","v":24,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"D12","v":2.8,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"E12","v":3.4,"in":true,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"F12","v":0.7,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G12","v":0.78,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H12","v":"U ≤ 2.67 / SHGC ≤ 0.25","bg":"#F8FAFC","al":"center"},{"c":"I12","v":"غير مطابق لمعامل SHGC","bg":"#FEE2E2","fg":"#991B1B","b":true,"al":"center"}]},{"r":13,"h":52.0,"cells":[{"c":"A13","v":3,"b":true,"al":"center"},{"c":"B13","v":"زجاج مزدوج عاكس 6+12+6 ملم فراغ هواء وإطار ألومنيوم مكسور حرارياً"},{"c":"C13","v":24,"in":true,"al":"center"},{"c":"D13","v":2.4,"in":true,"al":"center"},{"c":"E13","v":2.9,"in":true,"b":true,"al":"center"},{"c":"F13","v":0.32,"in":true,"al":"center"},{"c":"G13","v":0.25,"in":true,"al":"center"},{"c":"H13","v":"U ≤ 2.67 / SHGC ≤ 0.25","al":"center"},{"c":"I13","v":"مطابق جزئي (يلزم تحسين SHGC)","bg":"#FEF3C7","fg":"#92400E","b":true,"al":"center"}]},{"r":14,"h":52.0,"cells":[{"c":"A14","v":4,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"B14","v":"زجاج مزدوج منخفض الانبعاثية Low-E مع غاز الأرجون وإطار كسر حراري","bg":"#F8FAFC"},{"c":"C14","v":24,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"D14","v":1.4,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"E14","v":1.9,"in":true,"bg":"#F8FAFC","b":true,"al":"center"},{"c":"F14","v":0.23,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G14","v":0.55,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H14","v":"U ≤ 2.67 / SHGC ≤ 0.25","bg":"#F8FAFC","al":"center"},{"c":"I14","v":"مطابق لكود SBC 601","bg":"#DCFCE7","fg":"#166534","b":true,"al":"center"}]},{"r":15,"h":52.0,"cells":[{"c":"A15","v":5,"b":true,"al":"center"},{"c":"B15","v":"زجاج ثلاثي فائق الكفاءة Triple Low-E مع غاز الكريبتون للمشاريع المستدامة"},{"c":"C15","v":36,"in":true,"al":"center"},{"c":"D15","v":0.8,"in":true,"al":"center"},{"c":"E15","v":1.2,"in":true,"b":true,"al":"center"},{"c":"F15","v":0.19,"in":true,"al":"center"},{"c":"G15","v":0.48,"in":true,"al":"center"},{"c":"H15","v":"U ≤ 2.67 / SHGC ≤ 0.25","al":"center"},{"c":"I15","v":"مطابق ومتفوق لمعايير LEED","bg":"#DCFCE7","fg":"#166534","b":true,"al":"center"}]}]},{"name":"معاملات التوصيل SBC 601","maxRow":19,"maxCol":8,"colWidths":[12.0,36.0,24.0,26.0,24.0,22.0,24.0,46.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"دليل ومعاملات التوصيل الحراري للمواد الإنشائية والعازلة وفق كود البناء السعودي ومواصفات ساسو","bg":"#1E3A8A","fg":"#FFFFFF","b":true,"al":"center","cs":8},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":36.0,"cells":[{"c":"A2","v":"القيم التصميمية القياسية للتوصيل الحراري (λ) والكثافة (ρ) والسعة الحرارية النوعية (Cp) لمواد البناء والعزل | SBC 601 Table 5.1 / ISO 10456","bg":"#DBEAFE","fg":"#475569","al":"center","cs":8},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":28.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""},{"c":"G3","v":""},{"c":"H3","v":""}]},{"r":4,"h":52.0,"cells":[{"c":"A4","v":"كود المادة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B4","v":"اسم المادة الإنشائية أو العازلة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C4","v":"التصنيف الهندسي","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D4","v":"معامل التوصيل الحراري λ (W/m·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E4","v":"نطاق الكثافة التصميمية (kg/m³)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F4","v":"السعة الحرارية Cp (J/kg·K)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"G4","v":"معامل مقاومة بخار الماء (μ)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"H4","v":"الاستخدام النموذجي في المباني","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":5,"h":34.0,"cells":[{"c":"A5","v":"MAT-01","b":true,"al":"center"},{"c":"B5","v":"بوليسترين مبثوق (XPS)"},{"c":"C5","v":"عازل حراري رغوي صلب","al":"center"},{"c":"D5","v":0.028,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E5","v":"32 - 38","al":"center"},{"c":"F5","v":1450,"in":true,"al":"center"},{"c":"G5","v":150,"in":true,"al":"center"},{"c":"H5","v":"الأسطح المقلوبة، الجدران المزدوجة، الأساسات"}]},{"r":6,"h":34.0,"cells":[{"c":"A6","v":"MAT-02","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B6","v":"بوليسترين ممدد (EPS)","bg":"#F8FAFC"},{"c":"C6","v":"عازل حراري رغوي حبيبي","bg":"#F8FAFC","al":"center"},{"c":"D6","v":0.034,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E6","v":"20 - 30","bg":"#F8FAFC","al":"center"},{"c":"F6","v":1450,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G6","v":60,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H6","v":"نظام العزل الخارجي EIFS، حشوات الهوردي","bg":"#F8FAFC"}]},{"r":7,"h":34.0,"cells":[{"c":"A7","v":"MAT-03","b":true,"al":"center"},{"c":"B7","v":"بولي يوريثان صلب مرشوش (PUR)"},{"c":"C7","v":"عازل حراري رغوي مرشوش","al":"center"},{"c":"D7","v":0.023,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E7","v":"35 - 45","al":"center"},{"c":"F7","v":1500,"in":true,"al":"center"},{"c":"G7","v":80,"in":true,"al":"center"},{"c":"H7","v":"عزل متكامل للأسطح والزنك بدون فواصل"}]},{"r":8,"h":34.0,"cells":[{"c":"A8","v":"MAT-04","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B8","v":"بولي أيزوسيانورات (PIR)","bg":"#F8FAFC"},{"c":"C8","v":"عازل حراري صلب مقاوم للحريق","bg":"#F8FAFC","al":"center"},{"c":"D8","v":0.022,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E8","v":"32 - 40","bg":"#F8FAFC","al":"center"},{"c":"F8","v":1400,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G8","v":100,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H8","v":"ساندوتش بانل وأسطح المنشآت الصناعية","bg":"#F8FAFC"}]},{"r":9,"h":34.0,"cells":[{"c":"A9","v":"MAT-05","b":true,"al":"center"},{"c":"B9","v":"صوف صخري (Rockwool)"},{"c":"C9","v":"عازل حراري وصوتي ألياف معدنية","al":"center"},{"c":"D9","v":0.038,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E9","v":"40 - 100","al":"center"},{"c":"F9","v":840,"in":true,"al":"center"},{"c":"G9","v":1,"in":true,"al":"center"},{"c":"H9","v":"قواطع الجبس بورد، الجدران، عزل الدكت"}]},{"r":10,"h":34.0,"cells":[{"c":"A10","v":"MAT-06","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B10","v":"صوف زجاجي (Glasswool)","bg":"#F8FAFC"},{"c":"C10","v":"عازل ألياف زجاجية خفيفة","bg":"#F8FAFC","al":"center"},{"c":"D10","v":0.04,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E10","v":"16 - 32","bg":"#F8FAFC","al":"center"},{"c":"F10","v":840,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G10","v":1,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H10","v":"الأسقف المستعارة وتكسية مجاري الهواء","bg":"#F8FAFC"}]},{"r":11,"h":34.0,"cells":[{"c":"A11","v":"MAT-07","b":true,"al":"center"},{"c":"B11","v":"خرسانة خلوية معقمة (سيبوريكس AAC)"},{"c":"C11","v":"خرسانة خفيفة عازلة","al":"center"},{"c":"D11","v":0.12,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E11","v":"450 - 550","al":"center"},{"c":"F11","v":1000,"in":true,"al":"center"},{"c":"G11","v":7,"in":true,"al":"center"},{"c":"H11","v":"بلوك البناء الخارجي والقواطع الداخلية"}]},{"r":12,"h":34.0,"cells":[{"c":"A12","v":"MAT-08","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B12","v":"بلوك خرساني بركاني مفرغ (Pumice)","bg":"#F8FAFC"},{"c":"C12","v":"بلوك إسمنتي بركاني خفيف","bg":"#F8FAFC","al":"center"},{"c":"D12","v":0.38,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E12","v":"900 - 1100","bg":"#F8FAFC","al":"center"},{"c":"F12","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G12","v":10,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H12","v":"جدران البناء الخارجية المعزولة ذاتياً","bg":"#F8FAFC"}]},{"r":13,"h":52.0,"cells":[{"c":"A13","v":"MAT-09","b":true,"al":"center"},{"c":"B13","v":"بلوك خرساني عادي مفرغ (Hollow Concrete Block)"},{"c":"C13","v":"بلوك ركام عادي","al":"center"},{"c":"D13","v":0.9,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E13","v":"1300 - 1500","al":"center"},{"c":"F13","v":1000,"in":true,"al":"center"},{"c":"G13","v":12,"in":true,"al":"center"},{"c":"H13","v":"جدران البناء التقليدية الداخلية والخارجية"}]},{"r":14,"h":34.0,"cells":[{"c":"A14","v":"MAT-10","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B14","v":"طوب أحمر فخاري مفرغ (Clay Brick)","bg":"#F8FAFC"},{"c":"C14","v":"طوب طيني محروق","bg":"#F8FAFC","al":"center"},{"c":"D14","v":0.44,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E14","v":"800 - 1000","bg":"#F8FAFC","al":"center"},{"c":"F14","v":920,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G14","v":16,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H14","v":"جدران المباني السكنية خفيفة الوزن","bg":"#F8FAFC"}]},{"r":15,"h":34.0,"cells":[{"c":"A15","v":"MAT-11","b":true,"al":"center"},{"c":"B15","v":"خرسانة مسلحة عادية (Reinforced Concrete)"},{"c":"C15","v":"خرسانة إنشائية كثيفة","al":"center"},{"c":"D15","v":1.75,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E15","v":"2300 - 2400","al":"center"},{"c":"F15","v":1000,"in":true,"al":"center"},{"c":"G15","v":80,"in":true,"al":"center"},{"c":"H15","v":"الأعمدة، القواعد، الميدات، الأسقف"}]},{"r":16,"h":34.0,"cells":[{"c":"A16","v":"MAT-12","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B16","v":"بياض أسمنتي ورملي (Cement Plaster)","bg":"#F8FAFC"},{"c":"C16","v":"طبقة تشطيب ومحارة","bg":"#F8FAFC","al":"center"},{"c":"D16","v":0.72,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E16","v":"1800 - 1900","bg":"#F8FAFC","al":"center"},{"c":"F16","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G16","v":15,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H16","v":"لياسة الجدران الداخلية والأسقف","bg":"#F8FAFC"}]},{"r":17,"h":34.0,"cells":[{"c":"A17","v":"MAT-13","b":true,"al":"center"},{"c":"B17","v":"ألواح جبس بورد (Gypsum Plasterboard)"},{"c":"C17","v":"ألواح تشطيب جافة","al":"center"},{"c":"D17","v":0.25,"in":true,"b":true,"al":"center","nf":"#,##0.000"},{"c":"E17","v":"700 - 850","al":"center"},{"c":"F17","v":1000,"in":true,"al":"center"},{"c":"G17","v":10,"in":true,"al":"center"},{"c":"H17","v":"الأسقف المعلقة والقواطع الجدارية الجافة"}]},{"r":18,"h":34.0,"cells":[{"c":"A18","v":"MAT-14","bg":"#F8FAFC","b":true,"al":"center"},{"c":"B18","v":"حجر طبيعي صلب / جرانيت (Granite / Limestone)","bg":"#F8FAFC"},{"c":"C18","v":"كسوة خارجية صلبة","bg":"#F8FAFC","al":"center"},{"c":"D18","v":2.2,"in":true,"bg":"#F8FAFC","b":true,"al":"center","nf":"#,##0.000"},{"c":"E18","v":"2600 - 2800","bg":"#F8FAFC","al":"center"},{"c":"F18","v":1000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"G18","v":10000,"in":true,"bg":"#F8FAFC","al":"center"},{"c":"H18","v":"تكسية الواجهات الخارجية بالطريقة الميكانيكية","bg":"#F8FAFC"}]},{"r":19,"h":34.0,"cells":[{"c":"A19","v":"MAT-15","b":true,"al":"center"},{"c":"B19","v":"فراغ هوائي غير مهوى 20-50 ملم"},{"c":"C19","v":"فراغ عازل هوائي","al":"center"},{"c":"D19","v":"-","b":true,"al":"center"},{"c":"E19","v":"1.2","al":"center"},{"c":"F19","v":1005,"in":true,"al":"center"},{"c":"G19","v":1,"in":true,"al":"center"},{"c":"H19","v":"تجويف بين طبقتي الجدار المزدوج (R=0.18)"}]}]}]}