{"slug":"concrete-pre-pour-inspection-checklist","sheets":[{"name":"بيانات العنصر وتصريح الصب","maxRow":15,"maxCol":6,"colWidths":[8.0,56.0,18.0,14.0,22.0,22.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"بطاقة بيانات العنصر الخرساني وتصريح الصب (Concrete Pre-Pour Inspection & Pour Card)","bg":"#0F172A","fg":"#FFFFFF","b":true,"al":"center","cs":6},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":56.0,"cells":[{"c":"A2","v":"نموذج الفحص الشامل للشدة الخشبية، حديد التسليح، التمديدات الكهروميكانيكية، وجاهزية الصب طبقاً لـ ACI 318 و SBC 304","bg":"#1D4ED8","fg":"#DBEAFE","al":"center","cs":6},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":12.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""}]},{"r":4,"h":34.0,"cells":[{"c":"A4","v":"إجمالي بنود الفحص (Checkpoints)","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"C4","v":"البنود المطابقة (Passed Items)","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center","cs":2},{"skip":true},{"c":"E4","v":"كمية الخرسانة المصرح بصبها","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center"},{"c":"F4","v":"قرار تصريح الصب النهائي","bg":"#F1F5F9","fg":"#475569","b":true,"al":"center"}]},{"r":5,"h":42.0,"cells":[{"c":"A5","v":10,"f":"=COUNTA('قائمة الفحص والاستلام Pre-Pour'!A5:A14)","bg":"#E2E8F0","b":true,"al":"center","nf":"#,##0","cs":2},{"skip":true},{"c":"C5","v":0,"f":"=COUNTIF('قائمة الفحص والاستلام Pre-Pour'!E5:E14,\"*مطابق*\")","bg":"#DCFCE7","b":true,"al":"center","nf":"#,##0","cs":2},{"skip":true},{"c":"E5","v":145,"f":"=C12","bg":"#EFF6FF","b":true,"al":"center","nf":"#,##0.0"},{"c":"F5","v":"موقوف لحين تلافي الملاحظات","f":"=IF(B5=A5,\"مصرح بالصب (Approved to Pour)\",\"موقوف لحين تلافي الملاحظات\")","bg":"#DCFCE7","b":true,"al":"center"}]},{"r":6,"h":34.0,"cells":[{"c":"A6","v":"بند فحص إلزامي قبل الصب","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"C6","v":"بنود مستوفاة بالكامل","bg":"#F1F5F9","fg":"#64748B","al":"center","cs":2},{"skip":true},{"c":"E6","v":"متر مكعب (م3)","bg":"#F1F5F9","fg":"#64748B","al":"center"},{"c":"F6","v":"Pouring Authorization Status","bg":"#F1F5F9","fg":"#64748B","al":"center"}]},{"r":7,"h":14.0,"cells":[{"c":"A7","v":""},{"c":"B7","v":""},{"c":"C7","v":""},{"c":"D7","v":""},{"c":"E7","v":""},{"c":"F7","v":""}]},{"r":8,"h":38.0,"cells":[{"c":"A8","v":"جدول الإعدادات المركزية وفئات الأسعار والمعاملات (Central Setup & Dynamic Rates)","bg":"#1E293B","fg":"#FFFFFF","b":true,"cs":6},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":9,"h":40.0,"cells":[{"c":"A9","v":"م","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B9","v":"بيان المعامل / بند الإعداد المركزي","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C9","v":"القيمة / الفئة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D9","v":"الوحدة","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E9","v":"التوصيف الفني وملاحظات التطبيق","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center","cs":2},{"skip":true}]},{"r":10,"h":34.0,"cells":[{"c":"A10","v":1,"b":true,"al":"center"},{"c":"B10","v":"العنصر الإنشائي المطلوب صبه (Structural Element)","b":true},{"c":"C10","v":"سقف وكمرات الدور الأول","bg":"#EFF6FF","b":true,"al":"center"},{"c":"D10","v":"عنصر","fg":"#1E293B","al":"center"},{"c":"E10","v":"تحديد المحاور والمناسيب ورقم اللوحة التنفيذية المعتمدة","fg":"#1E293B","cs":2},{"skip":true}]},{"r":11,"h":34.0,"cells":[{"c":"A11","v":2,"b":true,"al":"center"},{"c":"B11","v":"إجهاد الخرسانة المطلوب ومحتوى الأسمنت (Concrete Grade)","b":true},{"c":"C11","v":"35 MPa (350 kg/m3)","bg":"#EFF6FF","b":true,"al":"center"},{"c":"D11","v":"رتبة","fg":"#1E293B","al":"center"},{"c":"E11","v":"خرسانة جاهزة بمحتوى أسمنتي لا يقل عن 350 كجم/م3 وهبوط 120±25 مم","fg":"#1E293B","cs":2},{"skip":true}]},{"r":12,"h":34.0,"cells":[{"c":"A12","v":3,"b":true,"al":"center"},{"c":"B12","v":"الكمية التقديرية للصب وعدد خلاطات ومضخات الخرسانة","b":true},{"c":"C12","v":145,"in":true,"bg":"#EFF6FF","b":true,"al":"center","nf":"#,##0.00"},{"c":"D12","v":"م3","fg":"#1E293B","al":"center"},{"c":"E12","v":"مضختان خرسانة + 4 هزازات ميكانيكية (2 أساسي + 2 احتياطي)","fg":"#1E293B","cs":2},{"skip":true}]},{"r":13,"h":34.0,"cells":[{"c":"A13","v":4,"b":true,"al":"center"},{"c":"B13","v":"الحد الأقصى لدرجة حرارة الخرسانة المسموح بها عند الصب","b":true},{"c":"C13","v":32,"in":true,"bg":"#EFF6FF","b":true,"al":"center","nf":"#,##0.00"},{"c":"D13","v":"درجة مئوية","fg":"#1E293B","al":"center"},{"c":"E13","v":"طبقاً لاشتراطات صب الخرسانة في الأجواء الحارة ACI 305 / SBC 304","fg":"#1E293B","cs":2},{"skip":true}]},{"r":14,"h":14.0,"cells":[{"c":"A14","v":""},{"c":"B14","v":""},{"c":"C14","v":""},{"c":"D14","v":""},{"c":"E14","v":""},{"c":"F14","v":""}]},{"r":15,"h":104.0,"cells":[{"c":"A15","v":"إعداد مهندس المكتب الفني / الحصر\nالاسم: .........................................\nالتوقيع والتاريخ: .............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true},{"c":"C15","v":"مراجعة وتدقيق مدير المشروع\nالاسم: .........................................\nالتوقيع والتاريخ: .............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true},{"c":"E15","v":"اعتماد الاستشاري / الإدارة المختصة\nالاسم: .........................................\nالتوقيع والختم: ...............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true}]}]},{"name":"قائمة الفحص والاستلام Pre-Pour","maxRow":16,"maxCol":6,"colWidths":[12.0,58.0,13.0,30.0,16.0,34.0],"rows":[{"r":1,"h":54.0,"cells":[{"c":"A1","v":"قائمة التحقق والفحص الميداني ما قبل صب الخرسانة المسلحة (Pre-Pour QC Inspection Checklist)","bg":"#0F172A","fg":"#FFFFFF","b":true,"al":"center","cs":6},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":2,"h":56.0,"cells":[{"c":"A2","v":"لا يصرح ببدء صب الخرسانة إلا بعد استيفاء كافة بنود الفحص التالية واعتماد مهندسي الإشراف (مدني + كهروميكانيك + مساحة)","bg":"#1D4ED8","fg":"#DBEAFE","al":"center","cs":6},{"skip":true},{"skip":true},{"skip":true},{"skip":true},{"skip":true}]},{"r":3,"h":12.0,"cells":[{"c":"A3","v":""},{"c":"B3","v":""},{"c":"C3","v":""},{"c":"D3","v":""},{"c":"E3","v":""},{"c":"F3","v":""}]},{"r":4,"h":40.0,"cells":[{"c":"A4","v":"كود الفحص","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"B4","v":"محور وبند الفحص الهندسي الموقعي قبل الصب","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"C4","v":"التخصص","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"D4","v":"المعيار المرجعي (Tolerance / Spec)","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"E4","v":"نتيجة الفحص","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"},{"c":"F4","v":"ملاحظات المهندس الاستشاري المشرف","bg":"#1E293B","fg":"#FFFFFF","b":true,"al":"center"}]},{"r":5,"h":52.0,"cells":[{"c":"A5","v":"CHK-01","b":true,"al":"center"},{"c":"B5","v":"مراجعة المحاور الإنشائية ومناسيب قاع وجوانب الشدة الخشبية وأبعاد القطاعات","b":true},{"c":"C5","v":"مساحة","fg":"#1E293B","al":"center"},{"c":"D5","v":"تفاوت مسموح ±5 مم طبقاً لـ ACI 117","fg":"#1E293B","al":"center"},{"c":"E5","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F5","v":"تم التدقيق بميزان القامة والتوتال ستيشن","b":true,"al":"center"}]},{"r":6,"h":52.0,"cells":[{"c":"A6","v":"CHK-02","b":true,"al":"center"},{"c":"B6","v":"فحص متانة الشدة الخشبية/المعدنية، تقسيط القوائم، البرندات، والجاكات الحاملة","b":true},{"c":"C6","v":"مدني","fg":"#1E293B","al":"center"},{"c":"D6","v":"قوائم كل 80 سم مع برندات أفقية ونهايز مائلة","fg":"#1E293B","al":"center"},{"c":"E6","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F6","v":"الشدة آمنة ومتزنة ضد أحمال الصب","b":true,"al":"center"}]},{"r":7,"h":34.0,"cells":[{"c":"A7","v":"CHK-03","b":true,"al":"center"},{"c":"B7","v":"التأكد من نظافة الشدة الخشبية من النشارة والأسلاك ورشها بالمياه قبل الصب","b":true},{"c":"C7","v":"مدني","fg":"#1E293B","al":"center"},{"c":"D7","v":"خلو تام من الشوائب والمواد العالقة","fg":"#1E293B","al":"center"},{"c":"E7","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F7","v":"تم التنظيف بالكمبروسر الهوائي","b":true,"al":"center"}]},{"r":8,"h":52.0,"cells":[{"c":"A8","v":"CHK-04","b":true,"al":"center"},{"c":"B8","v":"فحص أقطار وأعداد وتوزيع حديد التسليح السفلي والعلوي والحديد الإضافي","b":true},{"c":"C8","v":"مدني","fg":"#1E293B","al":"center"},{"c":"D8","v":"مطابق للوحة الشوب دروينج المعتمدة Code A","fg":"#1E293B","al":"center"},{"c":"E8","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F8","v":"تمت مراجعة الأقطار وأطوال الركوب 60D","b":true,"al":"center"}]},{"r":9,"h":52.0,"cells":[{"c":"A9","v":"CHK-05","b":true,"al":"center"},{"c":"B9","v":"فحص تكثيف كانات الأعمدة والكمرات في مناطق الاتصال والزلازل وأقفال الكانات","b":true},{"c":"C9","v":"مدني","fg":"#1E293B","al":"center"},{"c":"D9","v":"توزيع تبادلي للأقفال بزاوية 135 درجة","fg":"#1E293B","al":"center"},{"c":"E9","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F9","v":"تم تربيط كافة التقاطعات بسلك رباط","b":true,"al":"center"}]},{"r":10,"h":52.0,"cells":[{"c":"A10","v":"CHK-06","b":true,"al":"center"},{"c":"B10","v":"التأكد من تركيب البسكوت الخرساني/البلاستيكي والكراسي الحديدية لضبط الغطاء","b":true},{"c":"C10","v":"مدني","fg":"#1E293B","al":"center"},{"c":"D10","v":"غطاء 2.5 سم للبلاطات و 4 سم للكمرات والأعمدة","fg":"#1E293B","al":"center"},{"c":"E10","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F10","v":"البسكوت والكراسي موزعة كل 80 سم","b":true,"al":"center"}]},{"r":11,"h":52.0,"cells":[{"c":"A11","v":"CHK-07","b":true,"al":"center"},{"c":"B11","v":"فحص واستلام علب وخراطيم الكهرباء والتيار الخفيف المدفونة داخل السقف","b":true},{"c":"C11","v":"كهرباء","fg":"#1E293B","al":"center"},{"c":"D11","v":"مطابقة مخطط الكهرباء وتثبيت العلب بإحكام","fg":"#1E293B","al":"center"},{"c":"E11","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F11","v":"تم الاستلام والتوقيع من مهندس الكهرباء","b":true,"al":"center"}]},{"r":12,"h":52.0,"cells":[{"c":"A12","v":"CHK-08","b":true,"al":"center"},{"c":"B12","v":"فحص جرابات ومواسير السباكة والتكييف المارة بالكمرات أو البلاطات (Sleeves)","b":true},{"c":"C12","v":"ميكانيكا","fg":"#1E293B","al":"center"},{"c":"D12","v":"عدم قطع أي سيخ رئيسي وإضافة فواتير حول الفتحة","fg":"#1E293B","al":"center"},{"c":"E12","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F12","v":"تم الاستلام من مهندس الميكانيكا","b":true,"al":"center"}]},{"r":13,"h":52.0,"cells":[{"c":"A13","v":"CHK-09","b":true,"al":"center"},{"c":"B13","v":"التأكد من توافر الهزازات الميكانيكية، إضاءة الموقع، قمع المخروط، ومكعبات الفحص","b":true},{"c":"C13","v":"جودة QC","fg":"#1E293B","al":"center"},{"c":"D13","v":"6 مكعبات لكل 100 م3 + ترمومتر قياس حرارة","fg":"#1E293B","al":"center"},{"c":"E13","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F13","v":"فني المختبر متواجد بالموقع","b":true,"al":"center"}]},{"r":14,"h":52.0,"cells":[{"c":"A14","v":"CHK-10","b":true,"al":"center"},{"c":"B14","v":"توافر أغطية الخيش والبلاستيك ومصدر المياه للبدء في المعالجة فور الشك النهائي","b":true},{"c":"C14","v":"جودة QC","fg":"#1E293B","al":"center"},{"c":"D14","v":"معالجة مائية مستمرة لمدة لا تقل عن 7 أيام","fg":"#1E293B","al":"center"},{"c":"E14","v":"مطابق (Pass)","fg":"#1E293B","al":"center"},{"c":"F14","v":"مصرح ببدء أعمال صب الخرسانة","b":true,"al":"center"}]},{"r":15,"h":14.0,"cells":[{"c":"A15","v":""},{"c":"B15","v":""},{"c":"C15","v":""},{"c":"D15","v":""},{"c":"E15","v":""},{"c":"F15","v":""}]},{"r":16,"h":75.0,"cells":[{"c":"A16","v":"إعداد مهندس المكتب الفني / الحصر\nالاسم: .........................................\nالتوقيع والتاريخ: .............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true},{"c":"C16","v":"مراجعة وتدقيق مدير المشروع\nالاسم: .........................................\nالتوقيع والتاريخ: .............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true},{"c":"E16","v":"اعتماد الاستشاري / الإدارة المختصة\nالاسم: .........................................\nالتوقيع والختم: ...............................","bg":"#F1F5F9","b":true,"al":"center","cs":2},{"skip":true}]}]}]}